INSTALLATION GUIDE EN
Instructions in English
PELLET STOVE
FLUX HYDRO
PART 1 - REGULATIONS AND ASSEMBLY
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - FLUX HYDRO

INSTALLATION GUIDE ENInstructions in EnglishPELLET STOVEFLUX HYDROPART 1 - REGULATIONS AND ASSEMBLY

Página 2

82 - INSTALLATION INSTRUCTIONSRULES FOR INSTALLATION The product in question is a stove that uses wood pellets.Below is a list of the European regulat

Página 3 - INTRODUCTION

92 - INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibited15 Kg BAG OF FUELThe instructions in this chapter refe

Página 4

102 - INSTALLATION INSTRUCTIONSFOREWORDThe installation position must be chosen according to the room, to the smoke extraction system, to the chimney

Página 5

11min.3,5 metriAT(A)AP(B)2 - INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedFOREWORDThis chapter on the Sm

Página 6

12ABCDEABCD15°EFABCDE30°F2 - INSTALLATION INSTRUCTIONSTECHNICAL CHARACTERISTICSHave the eciency of the ue checked by an authorised technician.The u

Página 7 - INFORMATION

13ABD60°ECFABCDE45°F 2 - INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedROOF AT 60°

Página 8 - EXCLUSIONS

14199234567892 - INSTALLATION INSTRUCTIONSMAINTENANCEThe ue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section

Página 9 - SPARE PARTS

15AB BACMIN.1,5 m MIN.1,5 mMIN.1,5 mMIN.0,3 m2 - INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedEXTERNAL A

Página 10 - 2 - INSTALLATION INSTRUCTIONS

162 - INSTALLATION INSTRUCTIONSDISTANCE (metres) The air inlet must be at a distance of:1.5 m UNDER Windows, doors, smoke outlets, cavities, ...1.5 m

Página 11

17TISIUBAPUIIC43D2IEVU1F2 - INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedEXAMPLES OF CORRECT INSTALLATIO

Página 12

IITABLE OF CONTENTSTABLE OF CONTENTS ...IIINTRODUCTION ...

Página 13

182798 111183709 19735773ø80ø48989111997327998975993 - DRAWINGS AND TECHNICAL CHARACTERISTICSDRAWINGS AND CHARACTERISTICSFLUX HYDRO DIMENSIONS (dimens

Página 14

193 - DRAWINGS AND TECHNICAL CHARACTERISTICSTechnical Dept. - All rights reserved - Reproduction is prohibitedTECHNICAL CHARACTERISTICS FLUX HYDRONomi

Página 15

20ut4 - UNPACKINGPREPARATION AND UNPACKINGThe FLUX stove is delivered complete with all its electrical, mechanical, and hydraulic components after it

Página 16

211500MIN.300MIN.30010MIN.400MIN.18005 - POSITIONINGTechnical Dept. - All rights reserved - Reproduction is prohibitedREQUIREMENTS FOR INSTALLATION OF

Página 17

22P4 - UNPACKINGFOOT ADJUSTMENTThe underside of the stove is tted with adjustable feet.Use a spanner to unscrew the feet to adjust the length and mak

Página 18

23HHP4 - UNPACKINGTechnical Dept. - All rights reserved - Reproduction is prohibitedCONNECTION OF THE SMOKE OUTLET PIPEYou can choose whether to extra

Página 19

24AABDC6 - PANEL REMOVALCOVERING KIT The covering of the stove is composed of:• lateral side - 2 pieces• right front side - 1 piece• left front sid

Página 20 - DRAWINGS AND CHARACTERISTICS

25Bef gDh6 - PANEL REMOVALTechnical Dept. - All rights reserved - Reproduction is prohibitedFRONT LATERAL PANELS B-DThe rst thing to do is to x the

Página 21

26ilmxy6 - PANEL REMOVALPlace panels “B” and “D” making sure that wire “x” of the panel is aligned with wire “y” of the top of the structure.Ax panel

Página 22 - 4 - UNPACKING

27CDnoCD6 - PANEL REMOVALTechnical Dept. - All rights reserved - Reproduction is prohibitedAt this point, place the central panel “C” ensuring that sl

Página 23 - 5 - POSITIONING

1INTRODUCTIONTechnical Dept. - All rights reserved - Reproduction is prohibitedDear Customer, our products are designed and manufactured in compliance

Página 24

28pCq6 - PANEL REMOVALAdjustment of the central panel “C”.Loosen the three screws “p” and lower or raise the stopper “q” where the central panel “C” i

Página 25

29CrD6 - PANEL REMOVALTechnical Dept. - All rights reserved - Reproduction is prohibitedApplying side panelsPanel “D” (and the left one “B”) were prev

Página 26 - 6 - PANEL REMOVAL

30s6 - PANEL REMOVALApplying the central panelBoth side front panels (“B” and “D”) having been xed into place, you may proceed with applying panel “C

Página 27

31tAtWZ6 - PANEL REMOVALTechnical Dept. - All rights reserved - Reproduction is prohibitedApplying side panels “A”In order to install the side panels

Página 28

32uTkyj6 - PANEL REMOVALComplete top "T"Remove the three screws "u", loosen the two screws "k", the three screws “j”, an

Página 29

33pFC6 - PANEL REMOVALTechnical Dept. - All rights reserved - Reproduction is prohibitedACCESS TO THE ELECTRONIC BOARDTo access the electronic board y

Página 30

34UV6 - PANEL REMOVALLOADING THE PELLETSThe pellets can be loaded either manually or automatically. The tank can contain up to 57 litres or 40 kg of p

Página 31

356 - PANEL REMOVALTechnical Dept. - All rights reserved - Reproduction is prohibitedSAFETYPROCEDURE TO FOLLOW IF ANY SMOKE SPILLAGE IS SEEN WITHIN TH

Página 32

36798280A2ECA1CA2EA15591727 - HYDRAULIC CONNECTIONHYDRAULIC CONNECTIONCSAFETY VALVE 3 bar – 1/2” FA1Heating water supply 3/4”MESYSTEM EMPTYING 1/2”FA2

Página 33

377 - HYDRAULIC CONNECTIONTechnical Dept. - All rights reserved - Reproduction is prohibitedCONNECTING THE SYSTEMMake the connections to the correspon

Página 34

21 - WARNINGS AND WARRANTY CONDITIONSSAFETY PRECAUTIONS • Installation, electrical connection, function test and maintenance must only be carried out

Página 35

387 - HYDRAULIC CONNECTIONWATER CHARACTERISTICSThe characteristics of the water used to ll the system are very important to prevent the build-up of m

Página 36

39ONOFF8 - ELECTRICAL CONNECTIONTechnical Dept. - All rights reserved - Reproduction is prohibitedELECTRICAL CONNECTIONConnect the supply cable coming

Página 37

408 - ELECTRICAL CONNECTIONOPERATING MODEThe operating mode for hydro stoves is only AUTOMATIC (there is no manual operating mode available). The modu

Página 39

REV. 08901506100 12/01/2015Via La Croce n°833074 Vigonovo di Fontanafredda (PN) – ITALYTelephone: +39 0434/599599 r.a.Fax: +39 0434/599598Internet: ww

Página 40

31 - WARNINGS AND WARRANTY CONDITIONSTechnical Dept. - All rights reserved - Reproduction is prohibited• Any type of tampering or unauthorised replac

Página 41 - 8 - ELECTRICAL CONNECTION

41 - WARNINGS AND WARRANTY CONDITIONS• A carbon monoxide alarm must be tted in the room where the appliance is sited Refer too ADJ part 2.34 through

Página 42

51 - WARNINGS AND WARRANTY CONDITIONSTechnical Dept. - All rights reserved - Reproduction is prohibited INFORMATION• In case of any problems, get in

Página 43

61 - WARNINGS AND WARRANTY CONDITIONSEXCLUSIONSThe guarantee does not cover malfunctions and/or damage to the appliance that arise due to the followin